What is NAD+?
NAD+ (beta-nicotinamide adenine dinucleotide, oxidized form) is a dinucleotide coenzyme supplied as a powder for laboratory research. It is not a peptide: it is two nucleotides, one carrying nicotinamide and one carrying adenine, joined through a pyrophosphate bridge.
NAD+ structure
The free acid has the formula C21H27N7O14P2 and a weight of 663.43 g/mol (the sodium salt is 685.41 g/mol). The nicotinamide ring is the redox active part of the molecule. NAD+ absorbs at 260 nm through its adenine ring, while the reduced form NADH adds a second band at 340 nm, which is how the two forms are told apart spectroscopically.
Where this material appears in the literature
NAD+ appears throughout the biochemistry literature as an enzyme cofactor and as a substrate for sirtuins, PARPs and CD38 in cell based studies of energy metabolism and DNA repair. Kynvell BioLabs supplies the material for that kind of laboratory investigation and makes no claim about what it does in any living subject.
Related material in the catalog
NAD+ is held under featured research. Glutathione is the other coenzyme style reference material in the catalog.
Analysis and certification
Each lot is analyzed by an independent third-party laboratory before release. The current certificate reports purity by HPLC together with endotoxin and heavy metals results. The certificate of analysis is published in the COA Library against the lot number rather than against the product page, so the document you read is the document for the vial you receive. The lot number printed on the vial label is the link between the two.
Purity and the certificate
Purity is determined by HPLC peak area and reported for each lot on its certificate of analysis. The measured figure belongs to the lot it is published against, not to the product as a whole, which is why the lot number on the vial matters.
Where a figure on this page and a certificate differ, the certificate is the record that applies to your material. Analytical figures carry no implication of suitability for any purpose beyond laboratory research.
Research use only
Kynvell BioLabs supplies this material as a reference material for laboratory research. It is not supplied for any use in humans or animals, it is not a drug, dietary supplement, food or cosmetic, it has not been evaluated by the U.S. Food and Drug Administration, and nothing on this page describes or implies any such use. Sale is restricted to persons aged 18 or over who are qualified researchers or who purchase on behalf of a research institution, laboratory or business.
| Compound |
NAD+ |
| Also known as |
beta-Nicotinamide adenine dinucleotide (oxidized), nadide |
| Class |
Dinucleotide coenzyme (not a peptide) |
| Molecular formula |
C21H27N7O14P2 (free acid) |
| Molecular weight |
663.43 g/mol (free acid) |
| CAS number |
53-84-9 |
| Appearance |
White to off white powder |
| Purity |
Measured per lot, stated on the certificate of analysis |
| Purity method |
HPLC |
| Additional tests |
Endotoxin and heavy metals (current certificate) |
| Solubility |
Highly soluble in water for analytical preparation |
| Labeled quantity |
500 mg per vial |
Characterization. Values above describe the compound as supplied. The figures for the lot you receive, including measured purity, are stated on its certificate of analysis.
How this material is tested
The tests below are the methods used across the catalog. The current NAD+ certificate reports HPLC purity, endotoxin and heavy metals; check the certificate for the tests that apply to your lot.
- HPLC, for purity. High performance liquid chromatography separates the material into its components. The main peak is integrated against total peak area, and that ratio is the purity figure reported on the certificate.
- Mass spectrometry, for identity. Mass spectrometry confirms that the mass of the main component matches the expected mass for the compound, which is what distinguishes the correct sequence from a closely related one.
A complete certificate carries the compound name, the lot number, the test date, the method, the measured purity and the name of the laboratory. If any of those is missing, or the lot number on the vial does not match the certificate, contact us before using the material.
Storing NAD+
Move the sealed vial into freezer storage on arrival. Store it dry at −20°C or below, protected from light and moisture. Returned promptly to those conditions, the dry solid is the most stable form this material takes. NAD+ is hygroscopic and degrades in solution, faster at alkaline pH and at room temperature: keep the powder dry and prepare solutions in neutral buffer close to use.
Preparing stock solutions
Prepare stock solutions in sterile water or a neutral buffer at a concentration suited to your assay, expressed in mg/mL. Allow the vial to reach room temperature before opening, add solvent down the vial wall rather than directly onto the solid, and let the material dissolve without vigorous agitation. Solvent guidance for this material: highly soluble in water for analytical preparation.
Solutions are less stable than the dry solid. Prepare close to the point of use, hold at 2 to 8°C for short periods only, and aliquot before freezing so that repeated freeze and thaw cycles are avoided.
On arrival
Check that the vial is intact and sealed, that the compound name and labeled quantity match your order, and that the lot number on the label matches the certificate published for it in the COA Library. If anything does not match, or the packaging has clearly failed in transit, contact us before using the material and report it as soon as possible after delivery.
Handling and disposal
Assess the hazards of this material before handling it and use appropriate controls and protective equipment. It has not been fully characterized toxicologically and should be treated as potentially hazardous. Anyone handling it should be trained for the work.
Dispose of unused material, vials and packaging lawfully and in line with your institution's waste procedures.
Record keeping
Record the lot number in your notes at the point of first use, alongside the date the vial was opened and the concentration of any stock prepared. Certificates are published against the lot number rather than the product, so the lot number is the only reliable link between your results and the analytical data for the material that produced them. If a question arises about a result months later, that link is what keeps the work auditable.