What is IGF-1 LR3?
IGF-1 LR3 (Long R3 IGF-1) is an 83 residue analogue of human insulin-like growth factor 1, supplied as a lyophilized powder for laboratory research. It is a small protein rather than a short peptide, and it is widely used as a cell culture media supplement.
IGF-1 LR3 structure and sequence
IGF-1 LR3 is human IGF-1 with two changes: arginine in place of glutamic acid at position 3, and a 13 residue extension on the N terminus. It has 83 residues and three disulfide bonds, with a molecular weight of approximately 9111 Da. At this size it is characterized by intact mass rather than by sequence alone, and correct disulfide pairing matters for its structure.
Where this material appears in the literature
IGF-1 LR3 appears in the literature as a cell culture supplement and in IGF-1 receptor studies. The R3 substitution and the extension reduce its binding to IGF binding proteins, which is the property most studies examine. Kynvell BioLabs supplies the material for that kind of laboratory investigation and makes no claim about what it does in any living subject.
Related material in the catalog
IGF-1 LR3 is held under peptide research. It is the largest molecule in the catalog by some distance.
Analysis and certification
Kynvell BioLabs publishes certificates of analysis against lot numbers in the COA Library, with purity determined by HPLC and identity confirmed by mass spectrometry. A certificate for the current lot of IGF-1 LR3 is not yet published there. Check the COA Library for the lot number printed on your vial, or contact us before using the material.
Purity and the certificate
Purity is determined by HPLC peak area and reported for each lot on its certificate of analysis. The measured figure belongs to the lot it is published against, not to the product as a whole, which is why the lot number on the vial matters.
Where a figure on this page and a certificate differ, the certificate is the record that applies to your material. Analytical figures carry no implication of suitability for any purpose beyond laboratory research.
Research use only
Kynvell BioLabs supplies this material as a reference material for laboratory research. It is not supplied for any use in humans or animals, it is not a drug, dietary supplement, food or cosmetic, it has not been evaluated by the U.S. Food and Drug Administration, and nothing on this page describes or implies any such use. Sale is restricted to persons aged 18 or over who are qualified researchers or who purchase on behalf of a research institution, laboratory or business.
| Compound |
IGF-1 LR3 |
| Also known as |
Long R3 IGF-1, LR3-IGF-I |
| Class |
Recombinant polypeptide, human IGF-1 analogue |
| Amino acids |
83 |
| Sequence |
Human IGF-1 (70 residues) with Glu3 replaced by Arg, plus a 13 residue N terminal extension (Met-Phe-Pro-Ala-Met-Pro-Leu-Ser-Ser-Leu-Phe-Val-Asn); three disulfide bonds |
| Molecular formula |
C400H619N111O115S9 (disulfides formed) |
| Molecular weight |
approximately 9111 Da |
| CAS number |
143045-27-6 |
| Appearance |
White lyophilized powder |
| Purity |
Measured per lot, stated on the certificate of analysis |
| Purity method |
HPLC |
| Identity method |
Mass spectrometry |
| Solubility |
Reconstitute in dilute acid (for example 10 mM HCl) at 1 mg/mL or below, then dilute into buffer |
| Labeled quantity |
1 mg per vial |
Characterization. Values above describe the compound as supplied. The figures for the lot you receive, including measured purity, are stated on its certificate of analysis.
How this material is tested
Two separate analyses are carried out on a lot before its certificate is published, and both appear on the certificate.
- HPLC, for purity. High performance liquid chromatography separates the material into its components. The main peak is integrated against total peak area, and that ratio is the purity figure reported on the certificate.
- Mass spectrometry, for identity. Mass spectrometry confirms that the mass of the main component matches the expected mass for the compound, which is what distinguishes the correct sequence from a closely related one.
A complete certificate carries the compound name, the lot number, the test date, the method, the measured purity and the name of the laboratory. If any of those is missing, or the lot number on the vial does not match the certificate, contact us before using the material.
Storing IGF-1 LR3
Move the sealed vial into freezer storage on arrival. Store it dry at −20°C or below, protected from light and moisture. Returned promptly to those conditions, the dry solid is the most stable form this material takes. Avoid vortexing solutions: larger polypeptides can denature or adsorb to plastic when agitated hard. Low protein binding tubes are recommended.
Preparing stock solutions
Prepare stock solutions in dilute acid (for example 10 mM HCl) at a concentration suited to your assay, expressed in mg/mL. Allow the vial to reach room temperature before opening, add solvent down the vial wall rather than directly onto the solid, and let the material dissolve without vigorous agitation. Solvent guidance for this material: reconstitute in dilute acid (for example 10 mM HCl) at 1 mg/mL or below, then dilute into buffer.
Solutions are less stable than the dry solid. Prepare close to the point of use, hold at 2 to 8°C for short periods only, and aliquot before freezing so that repeated freeze and thaw cycles are avoided.
On arrival
Check that the vial is intact and sealed, that the compound name and labeled quantity match your order, and that the lot number on the label matches the certificate published for it in the COA Library. If anything does not match, or the packaging has clearly failed in transit, contact us before using the material and report it as soon as possible after delivery.
Handling and disposal
Assess the hazards of this material before handling it and use appropriate controls and protective equipment. It has not been fully characterized toxicologically and should be treated as potentially hazardous. Anyone handling it should be trained for the work.
Dispose of unused material, vials and packaging lawfully and in line with your institution's waste procedures.
Record keeping
Record the lot number in your notes at the point of first use, alongside the date the vial was opened and the concentration of any stock prepared. Certificates are published against the lot number rather than the product, so the lot number is the only reliable link between your results and the analytical data for the material that produced them. If a question arises about a result months later, that link is what keeps the work auditable.